4. Ensure that the hex on the rotary position sensor (2) fits in the hex of the motor/encoder housing (3).
5. Install the motor/encoder baseplate/gasket (1).

6. Install the motor/encoder to the transfer case.

Important:  When performing this service procedure, make sure that the motor/encoder unit is flat against the transfer case for proper installation.

7. Install motor/encoder mounting bolts to the transfer case.

Tighten the bolts to 16 Nm (12 ft. lbs.).

Notice:  Refer to Fastener Notice in Service Precautions.