Uplander FWD V6-3.5L VIN L (2006)
1. Install the recirculation actuator levers (3, 6), if necessary.
2. Install the recirculation actuator (7).
3. Install the recirculation actuator bolts/screws (1).
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten the screws to 1.2 N.m (11 lb in).
4. Connect the recirculation actuator electrical connector (1).
5. Install the upper I/P trim pad.
6. Re-calibrate the actuators. Refer to Re-Calibrating Actuators. See: Testing and Inspection/Programming and Relearning
Air Temperature Actuator Replacement - Auxiliary
AIR TEMPERATURE ACTUATOR REPLACEMENT - AUXILIARY
REMOVAL PROCEDURE