chevrolet Workshop Repair Guides

Chevrolet Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 1333 > < Diagram Information and Instructions|Page 1331
Page 1
background image

Refrigerant Pressure Sensor / Switch: Service and Repair

AIR CONDITIONING (A/C) REFRIGERANT PRESSURE SENSOR REPLACEMENT

TOOLS REQUIRED

J 39400-A Halogen Leak Detector

REMOVAL PROCEDURE

1. Disconnect the air conditioning (A/C) refrigerant pressure sensor electrical connector (1).
2. Remove the A/C refrigerant pressure sensor (2).
3. Inspect and replace the O-ring seal (3) as necessary.

INSTALLATION PROCEDURE

IMPORTANT:  DO NOT allow any of the mineral base 525 viscosity refrigerant oil on the O-ring seal to enter the refrigerant system.

Diagram Information and Instructions|Page 1333 > < Diagram Information and Instructions|Page 1331