V 30 P/U 4WD V6-262 4.3L (1987)
FIGURE 1 - MODEL 220 TBI
Bleed Orifice Installation Procedure
1.
Disconnect the EGR vacuum line currently on port "J" on the front of the TBI unit. See Figure 1.
2.
Install connector bleed assembly, P/N 10105820 on port "J" of the TBI unit.
3.
Reconnect the EGR vacuum line remove from port "J" to the open end of the connector bleed assembly.
Labor
Operation
Labor
Description
Number
Time
T7455
.3 Hours
Identify existing PROM
and install connector bleed assembly.
Add
.2 Hours
To change PROM if
necessary.