Venture AWD V6-3.4L VIN E (2004)
3. Install the 2 TP sensor fasteners, using a thread-locking compound on the screws. Loctite(R) 262, GM P/N #1052624, or equivalent should be
used.
Tighten
Tighten the TP sensor attaching screws to 2 N.m (18 lb in).
4. Connect the TP sensor electrical connector.
5. Connect the evaporative emission (EVAP) purge line.
6. Connect the fuel lines.
7. Install the air intake duct.