Voltage Signal: Description and Operation

BATTERY VOLTAGE - PCM INPUT

The direct battery feed to the PCM is used as a reference point to sense battery voltage.

In order for the PCM to operate, it must be supplied with battery voltage and ground. The PCM monitors the direct battery feed input to determine
battery charging rate and to control the injector initial opening point. It also has back-up RAM memory used to store Diagnostic Trouble Codes
(supply working DTC's). Direct battery feed is also used to perform key-OFF diagnostics and to supply working voltage to the controller for OBD
II.

If battery voltage is low the PCM will increase injector pulse width (period of time that the injector is energized).

Effect on Fuel Injectors

Fuel injectors are rated for operation at a specific voltage. If the voltage increases, the plunger will open faster and conversely, if voltage is low the
injector will be slow to open. Therefore, if sensed battery voltage drops, the PCM increases injector pulse-width to maintain the same volume of
fuel through the injector.

Charging

The PCM uses sensed battery voltage to verify that target charging voltage (determined by Battery Temperature Sensor) is being reached. To
maintain the target charging voltage, the PCM will full field the generator to 0.5 volt above target then turn OFF to 0.5 volt below target. This will
continue to occur up to a 100 Hz frequency (100 times per second).