chrysler Workshop Repair Guides

Chrysler Workshop Service and Repair Manuals

Controls - Front|Page 7740 > < Controls - Front|Page 7738
Page 3
background image

7. Position the blend door actuator (1) to the bottom of the HVAC housing (2). If necessary, rotate the actuator slightly to align the splines on the

actuator output shaft (3) with those on the blend-air door linkage (4).

8. Install the three screws (1) that secure the blend door actuator and cover (2) to the bottom of the HVAC housing (3). Tighten the screws to 2 Nm

(17 in. lbs.).

9. Connect the HVAC wire harness connector (1) to the blend door actuator. Make sure the wire harness is properly secured to the bottom of the

HVAC housing.

10. Reconnect the negative battery cable.

11. Initiate the Actuator Calibration function using a scan tool.

Removal

REMOVAL

WARNING:  On vehicles equipped with airbags, disable the airbag system before attempting any steering wheel, steering column, or
instrument panel component diagnosis or service. Disconnect and isolate the battery negative (ground) cable, then wait two minutes for the
airbag system capacitor to discharge before performing further diagnosis or service. This is the only sure way to disable the airbag system.
Failure to take the proper precautions could result in accidental airbag deployment and possible personal injury or death.

Controls - Front|Page 7740 > < Controls - Front|Page 7738