Aspen 2WD V8-4.7L Flex Fuel (2009)
black negative jumper cable (2) clamp to the negative (-) battery terminal (3). To prevent electrical arc, do not allow opposite ends of jumper cable
clamps to touch.
5. On the disabled vehicle, connect the red positive jumper cable (4) clamp to the positive (+) battery terminal (5). Connect the black negative
jumper cable (2) clamp to the engine ground (1) as close to the ground cable attaching point as possible.
6. Start the engine in the booster vehicle, let the engine idle a few minutes, and then start the engine in the disabled vehicle.
CAUTION: Do not crank starter motor on disabled vehicle for more than 15 seconds, starter will overheat and could fail.
7. Allow battery in the disabled vehicle to charge to at least 12.4 volts (75% charge) before attempting to start engine. If engine does not start within
15 seconds, stop cranking engine and allow starter to cool for 15 minutes before cranking again.
DISCONNECT CABLE CLAMPS AS FOLLOWS:
-
Disconnect black negative jumper cable (2) clamp from engine ground (1) on the disabled vehicle.
-
When using a booster vehicle, disconnect the black negative jumper cable (2) clamp from the negative battery terminal (3). Disconnect the red
positive jumper cable (4) clamp from the positive battery terminal (5).
-
Disconnect the red positive jumper cable (4) clamp from the positive battery terminal (4) on the disabled vehicle.