chrysler Workshop Repair Guides

Chrysler Workshop Service and Repair Manuals

Exhaust Manifold > < Catalytic Converter|Removal
Page 1
background image

Catalytic Converter: Service and Repair
Installation

3.7L/4.7L ENGINE

CAUTION: When servicing or replacing exhaust system components, disconnect the oxygen sensor connector(s). Allowing the exhaust to hang
by the oxygen sensor wires will damage the harness and/or sensor.

NOTE: The band clamps are not reusable. After removal, they must be replaced with new one.

1.   Make sure the catalytic converter assembly (3) is free of burrs.
2.   Insert the catalytic converter assembly (3) into the exhaust pipe (2).
3.   Make sure the alignment tang is fully seated in the alignment slot.
4.   Position catalytic converter assembly (3) to exhaust manifold and install flange nuts (5) and bolts (4). Do not tighten at this time.
5.   If other sections of the exhaust system where loosened in removal, refer to that information for the tightening procedures.
6.   At the catalytic converter-to-extension pipe connection, install new clamp (1) and nuts. Do not tighten at this time.
7.   Make sure the catalytic converter assembly (3) is correctly positioned and the properly aligned. The minimum clearance between components is 

25mm (1 inch). Ensure that muffler isolators are not stretched. Measurement between insulator rods is approximately 42 mm (1.65 in.). Make the
necessary adjustments, if necessary.

8.   Tighten exhaust manifold flange bolts to 33 Nm (25 ft. lbs.)
9.   Tighten the clamp nuts to 61 Nm (45 ft. lbs.) torque.

10.   Lower the vehicle.
11.   Start the engine, inspect for exhaust leaks. Repair exhaust leaks as necessary.

Exhaust Manifold > < Catalytic Converter|Removal