chrysler Workshop Repair Guides

Chrysler Workshop Service and Repair Manuals

Expansion Valve|Testing and Inspection > < A/C Expansion Valve - Description
Page 1
background image

Expansion Valve: Description and Operation
A/C Expansion Valve - Operation

Front

OPERATION

The A/C expansion valve controls the flow of high-pressure, low temperature liquid refrigerant entering the expansion valve and converts it into a
low-pressure, low-temperature mixture of liquid and gas before it enters the A/C evaporator. To meet the vehicles A/C cooling requirements, a
mechanical sensor is used in the A/C expansion valve to monitor the temperature and pressure of the refrigerant leaving the A/C evaporator and then
adjust the inlet port orifice size to allow only the proper amount of refrigerant to enter the evaporator. Controlling the refrigerant flow through the A/C
evaporator ensures that none of the refrigerant leaving the evaporator is still in a liquid state, which could damage the A/C compressor.

NOTE: Replacement of the refrigerant line O-ring seals and gaskets is required anytime a refrigerant line or expansion valve is disconnected.

Failure to replace the rubber O-ring seals and metal gaskets could result in a refrigerant system leak.

The A/C expansion valve is factory calibrated and cannot be adjusted or repaired and must be replaced if inoperative or damaged.

Rear

OPERATION

The rear A/C expansion valve controls the flow of high-pressure, low temperature liquid refrigerant entering the expansion valve and converts it into a
low-pressure, low-temperature mixture of liquid and gas before it enters the rear A/C evaporator. To meet the vehicles A/C cooling requirements, a
mechanical sensor is used in the rear A/C expansion valve to monitor the temperature and pressure of the refrigerant leaving the rear A/C evaporator and
then adjust the inlet port orifice size to allow only the proper amount of refrigerant to enter the evaporator. Controlling the refrigerant flow through the
rear A/C evaporator ensures that none of the refrigerant leaving the evaporator is still in a liquid state, which could damage the A/C compressor.

NOTE: Replacement of the refrigerant line O-ring seals and gaskets is required anytime a refrigerant line or expansion valve is disconnected.

Failure to replace the rubber O-ring seals and metal gaskets may result in a refrigerant system leak.

The rear A/C expansion valve is factory calibrated and cannot be adjusted or repaired and must be replaced if inoperative or damaged 

Expansion Valve|Testing and Inspection > < A/C Expansion Valve - Description