chrysler Workshop Repair Guides

Chrysler Workshop Service and Repair Manuals

Antilock Brake System Bleeding Procedures|Page 6958 > < Antilock Brake System Bleeding Procedures|Page 6956
Page 2
background image

^

Left rear wheel

^

Right front wheel

^

Right rear wheel

^

Left front wheel

1.

Attach a clear plastic hose to the bleeder screw starting at the right rear wheel and feed the hose into a clear jar containing enough fresh brake
fluid to submerge the end of the hose.

2.

Pump the brake pedal three or four times and hold it down before the bleeder screw is opened.

3.

Open the bleeder screw at least 1 full turn. When the bleeder screw opens the brake pedal will drop.

4.

Close the bleeder screw. Release the brake pedal only after the bleeder screw is closed.

5.

Repeat steps 1 through 3, four or five times at each bleeder screw. Then check the pedal for travel. If pedal travel is excessive or has not been
improved, enough fluid has not passed through the system to expel all the trapped air. Be sure to monitor the fluid level in the master cylinder
reservoir. It must stay at the proper level so air will not be allowed to re-enter the brake system.

6.

Test drive vehicle to be sure brakes are operating correctly and that pedal is solid.

Antilock Brake System Bleeding Procedures|Page 6958 > < Antilock Brake System Bleeding Procedures|Page 6956