Cirrus V6-2.5L VIN H (1995)
When Monitored:
With the engine running for more than 2 minutes and engine temperature greater than 176° F.
Set Condition:
The upstream oxygen sensor signal voltage is 0.5 volts for 1 minute.
Possible Causes:
-
Sensor output wire open
-
O2 sensor failure
-
PCM failure
-
Connector terminals
-
Connector wires