Oxygen Sensor: Specifications
-
After removing the sensor, the exhaust manifold threads must be cleaned with an 18 mm X 1.5 + 6E tap.
-
If reusing the original sensor, coat the sensor threads with an anti-seize compound such as Loctite (R) 771-64 or equivalent.
-
New sensors have compound on the threads and do not require an additional coating.
-
Tighten the sensor to 28 Nm (20 ft. lbs.) torque.