chrysler Workshop Repair Guides

Chrysler Workshop Service and Repair Manuals

Expansion Valve|Locations|Page 5934 > < Expansion Valve|Locations|Page 5932
Page 1
background image

Expansion Valve: Testing and Inspection

The expansion valve can fail in three different positions (open, closed, and restricted).

IN AND OPEN POSITION

This will result in a noisy compressor or no cooling. The cause can be a broken spring, broken ball or excessive moisture in the A/C system. If the
spring and ball are found to be defective, replace the expansion valve. If excessive moisture is found in the A/C system, recycle the refrigerant.

IN A CLOSED POSITION

There will be little or no suction pressure and no cooling. This may be caused by a failed power dome or excessive moisture in the A/C system. If
the power dome on the expansion valve is found to be defective, replace the expansion valve. If excessive moisture is found recycle the refrigerant.

A RESTRICTED ORIFICE

There will be low suction pressure and no cooling. This may be caused by debris in the refrigerant system. If debris in the system is believed to be
the cause, recycle the refrigerant and replace the expansion valve and the receiver drier.  

Expansion Valve|Locations|Page 5934 > < Expansion Valve|Locations|Page 5932