SOLENOID VALVE
DESCRIPTION
The BAS solenoid valve (2) is an electrically activated device used to increase brake assist.
The BAS solenoid valve (2) cannot be serviced. The power brake booster must be replaced in the event of a BAS solenoid valve failure.
OPERATION
The BAS solenoid valve is activated by the Controller Antilock Brake (CAB) Module. When activated, a poppet valve opens and allows atmospheric
pressure to enter the rear of the power brake booster diaphragm and increases the brake pressure.
REMOVAL
The solenoid valve is part of the brake booster assembly. Refer to the brake booster removal procedure.
INSTALLATION
The solenoid valve is part of the brake booster assembly. Refer to the brake booster installation procedure.