Measure the voltage of the Charge Air Cooler Circulation Pump Driver circuit at the input cavity of Fuse 13.

Is the voltage above 10 volts?

Yes >> Go To 4
No >> Go To 6

4. FUSED CHARGE AIR COOLER CIRCULATION PUMP DRIVER CIRCUIT OPEN 

Turn the ignition off. Disconnect the Charge Air Cooler Circulation Pump harness connector.

Note:  Check connectors - Clean/repair as necessary.

Measure the resistance of the Fused Charge Air Cooler Circulation Pump Driver circuit from the Charge Air Cooler Circulation Pump harness
connector to the Fuse 13 output cavity.

Is the resistance below 5.0 ohms?

Yes >> Go To 5
No >> Repair the Fused Charge Air Cooler Circulation Pump Driver circuit for an open. Perform the POWERTRAIN VERIFICATION TEST
- VER 2 See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Diagnostic Trouble Code Tests and Associated
Procedures/Verification Tests/Powertrain Verification Test - Ver 2.

5. CHARGE AIR COOLER CIRCULATION PUMP GROUND CIRCUIT OPEN 

With the ignition off.
Measure the resistance between ground and the Ground circuit at the Charge Air Cooler Circulation Pump harness connector.

Is the resistance below 5.0 ohms?

Yes >> Replace the Charge Air Cooler Circulation Pump. Perform the POWERTRAIN VERIFICATION TEST - VER 2 See: Powertrain

Supercharger Coolant Pump|Diagrams|Page 1630 > < Supercharger Coolant Pump|Diagrams|Page 1628