Variable Induction Control Valve: Service and Repair
Fig 54 Retaining Clip
REMOVAL
1. Disconnect negative battery cable.
2. Disconnect electrical connector (Fig. 53).
3. Remove manifold tuning valve mounting screws. Remove tuning valve.
INSTALLATION
1. Install tuning valve.
-
Tighten mounting screws to 11 Nm (8 ft. lbs.) torque.
2. Install electrical connector.