chrysler Workshop Repair Guides

Chrysler Workshop Service and Repair Manuals

Removal and Replacement|Page 7638 > < Removal and Replacement|Page 7636
Page 4
background image

3. Remove the three screws (1) that secure the recirculation door actuator (2) to the left side of the air inlet housing (3) and remove the actuator.

NOTE: Remove the recirculation door pivot lever by carefully pulling it straight out from the end of the recirculation door pivot shaft.

4. Remove the recirculation door pivot lever (1) from the end of the recirculation door pivot shaft on the driver side of the air inlet housing (2).

NOTE: If the foam seal on the air inlet housing is deformed or damaged, the seal must be replaced.

5. Carefully cut the foam seal (1) along the parting line (2) of the two halves of the air inlet housing (5). If the seal is deformed or damaged, it must

be replaced.

6. Remove the screws (4) that secure the two halves of the air inlet housing together.
7. Carefully separate the two halves of the air inlet housing and remove the recirculation-air door (3).

HVAC Housing

Removal and Replacement|Page 7638 > < Removal and Replacement|Page 7636