chrysler Workshop Repair Guides

Chrysler Workshop Service and Repair Manuals

Downstream O2 Sensor Heater Failure|Page 4526 > < Downstream O2 Sensor Heater Failure|Page 4524
Page 1
background image

Oxygen Sensor: Description and Operation
Downstream O2 Sensor Shorted to Voltage

NAME OF CODE:

Downstream O2S Shorted To Voltage

WHEN MONITORED:

With the ignition key ON.

SET CONDITION:

The downstream oxygen sensor signal voltage is above 1.2 volts.

THEORY OF OPERATION:

The downstream oxygen sensor is a voltage generating device. The PCM receives exhaust gas information from this O2 sensor. The sensor detects
exhaust gas content by a galvanic reaction within the sensor that produces a voltage. After measuring the amount of oxygen in the exhaust gases,
the downstream oxygen sensor tells the Powertrain Control Module (PCM) how well the catalytic converter is oxidizing HC and CO components
and reducing NOx components in the engine exhaust gas. Variations in the signals from this O2 sensor serve as an indicator of oxygen content.
The catalytic converter absorbs the oxygen in the exhaust gas when the fuel/air mixture is lean. The downstream O2 sensor indicates a deficiency
of oxygen when the upstream O2 sensor detects an abundance of oxygen and vice versa.

POSSIBLE CAUSES:

-

Sensor output wire shorted to another circuit

-

Dirty/wet connection causing voltage tracking in connector

-

O2 sensor failure 

Downstream O2 Sensor Heater Failure|Page 4526 > < Downstream O2 Sensor Heater Failure|Page 4524