Sebring V6-2.5L SOHC 24 Valve (1996)
Main Relay (Computer/Fuel System): Testing and Inspection
MFI Relay (ASD) And Fuel Pump Relay Check
1. Remove the relay.
2. Check that there is continuity between (4) and (6) terminals.
-
Standard value: 35-75 ohms
3. Use jumper leads to connect relay terminal No. 6 to the battery (+) terminal and terminal No. 4 to the battery (-) terminal.
-
Check the continuity between relay terminals No.2 and No.8 while connecting and disconnecting the jumper lead at the battery (-) terminal.
Jumper lead Continuity between terminals No.2 and 8
-
Connected = Continuity (0 ohms)
-
Disconnected = No continuity (infinite resistance)
4. If there is a defect, replace the relay.