Sebring V6-2.5L VIN N (1997)
Oxygen Sensor: Testing and Inspection
Downstream Sensor
Heated Oxygen Sensor Check
1. Disconnect the heated oxygen sensor connection
2. Check that there is continuity between following terminals:
-
Front bank side -- terminals 1 & 3
-
Rear bank side -- terminals 3 & 4
3. If there is no continuity, replace the heated oxygen sensor.
NOTE: If the scan tool does not display the standard value although no malfunction is found by the above-mentioned continuity test and harness check,
replace the heated oxygen sensor.