Sebring Convertible V6-2.5L SOHC 24 Valve (1996)
EGR Backpressure Transducer: Service and Repair
EGR Valve and Electric EGR Transducer Replacement
Fig. 2 EGR Control Valve
Fig. 3 EGR Valve
NOTE: If the EGR system operates incorrectly, replace the entire EGR valve and transducer together. The EGR valve and electrical transducer are
calibrated together.
NOTE: The EGR valve attaches to the front exhaust manifold. The transducer/solenoid attach to the front cylinder head (Fig. 3).
REMOVAL
1. Disconnect vacuum supply and outlet hose from solenoid.
2. Disconnect electrical connector from solenoid.
3. Remove back-pressure hose from transducer.
4. Pull transducer/solenoid up off of bracket.