chrysler Workshop Repair Guides

Chrysler Workshop Service and Repair Manuals

Blend Door Actuator - Removal|Page 6088 > < Blend Door Actuator - Removal|Page 6086
Page 3
background image

Installation.

5. Reconnect the negative battery cable.
6. Initiate the Actuator Calibration function using a scan tool .  See: Testing and Inspection/Component Tests and General Diagnostics/HVAC

System Test  

Recirculation Door Actuator - Removal

REMOVAL

WARNING: Disable the airbag system before attempting any steering wheel, steering column or instrument panel component diagnosis or

service. Disconnect and isolate the negative battery (ground) cable, then wait two minutes for the airbag system capacitor to
discharge before performing further diagnosis or service. This is the only sure way to disable the airbag system. Failure to follow
these instructions may result in accidental airbag deployment and possible serious or fatal injury.

NOTE: Illustration shown with instrument panel removed for clarity.

NOTE: LHD model shown. RHD model similar.

1. Disconnect and isolate the negative battery cable.
2. Remove the glove box bin See: Body and Frame/Interior Moulding / Trim/Glove Compartment/Service and Repair/Instrument Panel Glove Box -

Removal.

3. Reach through the glove box opening in the instrument panel and remove the screws (1) that secure the recirculation door actuator (2) to the right

side of the HVAC air inlet housing (3).

4. Disconnect the wire harness connector (4) from the recirculation door actuator and remove the actuator.

Recirculation Door Actuator - Installation

INSTALLATION

NOTE: Illustrations shown with instrument panel removed for clarity.

Blend Door Actuator - Removal|Page 6088 > < Blend Door Actuator - Removal|Page 6086