1. The normally open-type When a normally open relay as illustrated here is checked, there should be no continuity between terminals 3 and 4
when the relay is deenergized. There should be continuity between terminals 3 and 4 when battery voltage and ground are applied to
terminals 1 and 2. The relay condition is determined by this check.
NOTE: Check the relay in both situation which is energized and is not energized.
2. The normally closed-type When a normally closed relay as illustrated here is checked, there should be continuity between terminals 3 and 4
when the relay is deenergized. There should be no continuity between terminals 3 and 4 when battery voltage and ground are applied to
terminals 1 and 2. The relay condition is determined by this check.
NOTE: Check the relay in both situation which is energized and is not energized.
Checking Switches
In a circuit diagram, a switch is shown in the normal condition.
1. Normally open or normally closed switch
Switches are classified into those which open the circuit and those which close the circuit when off.
Switches are shown in their normal state unless specified otherwise.