Sebring LX Coupe V6-3.0L VIN H (2002)
STEP 1. Check the battery power supply circuit to the ETACS-ECU. Test at ETACS-ECU connector C-319.
1. Disconnect ETACS-ECU connector C-319 and measure the voltage available at the junction block side of the connector.
2. Measure the voltage between terminal 2 and ground.
-
The voltage should measure approximately 12 volts (battery positive voltage).
Q: Is the measured voltage approximately 12 volts (battery positive voltage)?
YES : Go to Step 4.
NO : Go to Step 2.