Sebring LX Coupe V6-3.0L VIN H (2002)
2. Measure the voltage between terminal 3 and ground by backprobing.
-
The voltage should measure approximately 12 volts (battery positive voltage).
Q: Is the measured voltage approximately 12 volts (battery positive voltage)?
YES : Go to Step 7.
NO : Go to Step 5.
STEP 5. Check sunroof motor assembly connector D-08 for loose, corroded or damaged terminals, or terminals pushed back in the connector.
Q: Is the sunroof motor assembly connector D-08 in good condition?
YES : Go to Step 6.
NO : Repair or replace the damaged components). Refer to Harness Connector Inspection. The sunroof function should work now normally.