A/T CONTROL RELAY CHECK
1. Remove the A/T control relay.
2. Use jumper wires to connect the A/T control relay terminal 2 to the positive battery terminal and terminal 3 to the negative battery terminal.
3. Check the continuity between terminal 1 and terminal 4 of the A/T control relay when the jumper wires are connected to and disconnected from
the battery.