Sebring Sedan L4-2.4L (2007)
NOTE: Illustration shown with instrument panel removed for clarity.
3. Connect the left floor duct (1) to the left side of the HVAC housing (2). Make sure the duct is fully engaged to the housing.
4. Install the screw (4) that secures the left floor duct to the HVAC housing. Tighten the screw to 2 Nm (17 in. lbs.).
5. On LHD models, connect the shift interlock cable (3) to the left floor duct.
6. On RHD models, install the glove box bin.
REAR FLOOR DISTRIBUTION DUCTS
7. Connect the left rear floor distribution duct (1) and the right rear floor distribution duct (2) as required to the HVAC housing (3). Make sure the
ducts are fully engaged to the housing.
8. Install the rear seat floor ducts.
9. Install the instrument panel.
REAR SEAT FLOOR DUCTS