Sebring Sedan L4-2.4L (2007)
2. Install the recirculation door pivot shaft adapter (3) into the right side pivot shaft of the recirculation air-door. Make sure the adapter is fully
engaged to the pivot shaft.
3. Install the recirculation door actuator (1) onto the right side of the air inlet housing (2). If necessary, rotate the actuator slightly to align the splines
of the actuator output shaft (3) with those on the recirculation door pivot shaft adapter (4).
4. Install the air inlet housing (3) onto the HVAC housing (1).
5. Install the HVAC housing assembly.
HVAC Housing
HOUSING-HVAC