Installation
INSTALLATION
SEDAN MODEL
NOTE: Take the proper precautions to protect the front face of the overhead console from cosmetic damage while performing this procedure.
NOTE: Typical overhead console shown. Infrared sensor location may vary by model.
1. Position the infrared sensor (3) onto the back of the overhead console (1). Align the slot on the front of the sensor with the tabs (4) on the console.
2. Install the screw (2) that secures the infrared sensor to the overhead console. Tighten the screw to 1.2 Nm (10 in. lbs).
3. Install the overhead console.
4. Reconnect the negative battery cable.
CONVERTIBLE MODEL