Recirculation Door
6. With a small screw driver, depress recirculation door gear release and remove gear.
7. Tilt the gear end of the recirculation door up and pull the door out of the housing.
8. Remove blower motor wiring connector.
9. Remove blower motor mounting screws and remove motor.
HVAC Harness
10. Remove HVAC harness connector from the top of the housing.