chrysler Workshop Repair Guides

Chrysler Workshop Service and Repair Manuals

Symptom Related Diagnostic Procedures|Page 437 > < Symptom Related Diagnostic Procedures|Page 435
Page 1
background image

Body Control Module: Scan Tool Testing and Procedures

DRB III Error Messages and Blank Screen

Under normal operation, the DRBIII(R) will display one of only two error messages: user-requested WARM Boot or User-Requested COLD Boot. If the
DRBIII(R) should display any other error message, record the entire display and call the Star Center. This is a sample of such an error message display:

ver: 2.14
date: 26 Jul93 
file: key_itf.cc
date: Jul 26 1993 
line: 548
err: 0x1
User-Requested COLD Boot

Press MORE to switch between this display and the application screen. Press F4 when done noting information.

DRB III Safety Information

WARNING: EXCEEDING THE LIMITS OF THE DRBIII(R) MULTIMETER IS DANGEROUS. READ ALL DRBIII(R) INSTRUCTIONS
BEFORE USING THE MULTIMETER. FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN PERSONAL INJURY OR
DEATH.

-

Follow the vehicle manufacturer's service specifications at all times.

-

Do not use the DRBIII(R) if it has been damaged.

-

Do not use the test leads if the insulation is damaged or if metal is exposed.

-

To avoid electrical shock, do not touch the test leads, tips, or the circuit being tested.

-

Choose the proper range and function for the measurement. Do not try voltage or current measurements that may exceed the rated capacity

-

Do not exceed the limits shown in the table:

-

Ohms cannot be measured if voltage is present. Ohms can be measured only in a non-powered circuit.

-

Voltage between any terminal and ground must not exceed 500v DC or 500v peak AC.

-

Use caution when measuring voltage above 25v DC or 25v AC.

-

The circuit being tested must be protected by a 10A fuse or circuit breaker.

-

Use the low current shunt to measure circuits up to 10A. Use the high current clamp to measure circuits exceeding 10A.

-

When testing for the presence of voltage or current, make sure the meter is functioning correctly. Take a reading of a known voltage or current
before accepting a zero reading.

-

When measuring current, connect the meter in series with the load.

-

Disconnect the live test lead before disconnecting the common test lead.

-

When using the meter function, keep the DRBIII(R) away from spark plug or coil wires to avoid measuring error from outside interference.

DRB III Does Not Power Up

If the LED's do not light or no sound is emitted at start up, check for loose cable connections or a bad cable. Check the vehicle battery voltage (data link
connector cavity 16). A minimum of 11 volts is required to adequately power the DRBIII(R). Check for proper grounds at DLC cavities 4 and 5.

If all connections are proper between the DRBIII(R) and the vehicle or other devices, and the vehicle battery is fully charged, and inoperative DRBIII(R)
may be the result of faulty cable or vehicle wiring.

Display Is Not Visible

Symptom Related Diagnostic Procedures|Page 437 > < Symptom Related Diagnostic Procedures|Page 435