chrysler Workshop Repair Guides

Chrysler Workshop Service and Repair Manuals

Solar Sensor, HVAC|Locations|Page 908 > < Solar Sensor, HVAC|Locations|Page 906
Page 1
background image

Solar Sensor: Testing and Inspection

SUN SENSOR

WARNING: ON VEHICLES EQUIPPED WITH AIR-BAGS, DISABLE THE AIRBAG SYSTEM BEFORE ATTEMPTING ANY STEERING
WHEEL, STEERING COLUMN, OR INSTRUMENT PANEL COMPONENT DIAGNOSIS OR SERVICE. DISCONNECT AND ISOLATE
THE BATTERY NEGATIVE (GROUND) CABLE, THEN WAIT TWO MINUTES FOR THE AIRBAG SYSTEM CAPACITOR TO
DISCHARGE BEFORE PERFORMING FURTHER DIAGNOSIS OR SERVICE. THIS IS THE ONLY SURE WAY TO DISABLE THE
AIRBAG SYSTEM. FAILURE TO TAKE THE PROPER PRECAUTIONS COULD RESULT IN AN ACCIDENTAL AIRBAG
DEPLOYMENT AND POSSIBLE PERSONAL INJURY.

The sun sensor is located so the sun hits the sensor in the same way that it hits the driver and the passenger. It is important that the area in front of the
sensor be unobstructed. Check that the following items are not in the way of the sun sensor.

-

Windshield wipers that are adjusted too high.

-

Stickers on the windshield that are directly in front of the sensor.

-

Top cover which is not properly installed. The sun sensor should be 1/4 inch. above the top cover.

-

Caps or papers which might cover the sensor. Some ATC equipped vehicles may exhibit a lack of passenger comfort in sunny weather such as in
the early afternoon. Verify that the ATC system is functioning properly. Inspect the location of the sun sensor. The sun sensor must protrude
approximately 1/4 inch above the instrument panel top cover to insure proper operation. If the sensor does not protrude 1/4 inch, perform the
following procedure:

-

Confirm that the top cover is properly installed

-

Remove the top cover

-

Remove fasteners from sun sensor

-

Install one 1/4-20 nut per fastener under the sun sensor so that it is shimmed higher

-

Reinstall the sun sensor. Do not overtighten screw. If a longer screw is required, use 8-15x1 inch.

Solar Sensor, HVAC|Locations|Page 908 > < Solar Sensor, HVAC|Locations|Page 906