chrysler Workshop Repair Guides

Chrysler Workshop Service and Repair Manuals

Blend Door Actuator - Removal|Page 5710 > < Blend Door Actuator - Removal|Page 5708
Page 2
background image

Panel Glove Box - Installation.

5. Reconnect the negative battery cable.
6. Initiate the Actuator Calibration function using a scan tool .  See: Testing and Inspection/Component Tests and General Diagnostics/HVAC

System Test

Mode Door Actuator - Removal

REMOVAL

WARNING: Disable the airbag system before attempting any steering wheel, steering column or instrument panel component diagnosis or

service. Disconnect and isolate the negative battery (ground) cable, then wait two minutes for the airbag system capacitor to
discharge before performing further diagnosis or service. This is the only sure way to disable the airbag system. Failure to follow
these instructions may result in accidental airbag deployment and possible serious or fatal injury.

NOTE: LHD model shown. RHD model similar.

1. Disconnect and isolate the negative battery cable.
2. Remove the glove box binSee: Body and Frame/Interior Moulding / Trim/Glove Compartment/Service and Repair/Instrument Panel Glove Box -

Removal.

3. Remove the screws (1) that secure the mode door actuator (4) to the bracket (5) located on the right side of the HVAC air distribution housing (2).
4. Disconnect the wire harness connector (3) from the mode door actuator and remove the actuator.

Mode Door Actuator - Installation

INSTALLATION

1. Position the mode door actuator (4) onto the bracket (5) located on the right side of the HVAC air distribution housing (2). If necessary, rotate the

actuator slightly to align the splines on the actuator output shaft with those in the mode air door linkage.

2. Install the screws (1) that secure the mode door actuator to the air distribution housing. Tighten the screws to 2 Nm (17 in. lbs.).
3. Connect the wire harness connector (3) to the mode door actuator.
4. Install the glove box binSee: Body and Frame/Interior Moulding / Trim/Glove Compartment/Service and Repair/Instrument Panel Glove Box -

Blend Door Actuator - Removal|Page 5710 > < Blend Door Actuator - Removal|Page 5708