Oxygen Sensor: Service and Repair
Downstream O2 Sensor

REMOVAL - DOWNSTREAM 1/2

1. Disconnect the negative battery cable. 
2. Raise and support the vehicle. 

Fig. 26 Downstream Oxygen Sensor(1/2)

3. Disconnect the electrical connector. 

Fig. 27 Downstream 2/1 O2 Sensor

4. Use a socket such as the Snap-On YA8875 or equivalent to remove the sensor.
5. When the sensor is removed, the threads must be cleaned with an 18 mm X 1.5 + 6E tap. If using the original sensor, coat the threads with Loctite

771 - 64 anti-seize compound or equivalent.

INSTALLATION - DOWNSTREAM 2/1

The O2S is located on the side of the catalytic converter.

Threads of new oxygen sensors are factory coated with anti-seize compound to aid in removal. DO NOT add any additional anti-seize compound to