chrysler Workshop Repair Guides

Chrysler Workshop Service and Repair Manuals

Control Assembly, HVAC|Diagrams|Page 4883 > < Control Assembly, HVAC|Diagrams|Page 4881
Page 2
background image

Radio Bezel and HVAC Control, Rear Blower Motor Switch and Zone Control

Mode, Blend and Zone (if equipped) door calibration compensates for mechanical variations in the actuators, HVAC control module and its linkages.
In-vehicle calibration can be entered from the control's front panel. Diagnostics will always occur during Calibration Diagnostic and Cooldown test.

DIAGNOSTICS

During the Actuator calibration, diagnostics are performed on the actuators and evaporator temperature Fin Sensor. Once diagnostics are completed
the HVAC control head LED's will stop flashing to indicate a successful calibration. At this time manual testing of the Blend, Mode and Driver (if
equipped) potentiometers can be performed. If a failure is detected during Diagnostics a fault will be set in the control. When Ignition is cycled OFF
and then ON or Diagnostics is aborted, the LED flashing will stop. The only way to clear the failure codes is repeat the Calibration Diagnostic and
Cooldown test, after all repairs are completed.

COOLDOWN TEST

This test has been designed for performance testing of the A/C system at the manufacturing facility. If the HVAC control module is replaced, the
Cooldown test must be run after the Calibration test. Cooldown will not occur on Heater Only units. During the Cooldown test the control will monitor
the temperature of the Fin Sensor. The A/C system must be able to bring the evaporator temperature down a predetermined minimum amount in less
than 2 minutes.

CALIBRATION/COOLDOWN LED DISPLAY CODES

Calibration/Cooldown LED Display Codes

See chart for definition of the flashing LED's noted before ignition cycled off. If no problems are found,the control functions normally.

NOTE:  Calibration is run automatically whenever the control head detects a "new" VIN number. Calibration may be initiated manually by pressing
and holding WASH and REAR WIPER buttons for 5 seconds.

COOLDOWN TEST ENTRY

To Initiate Test:
-

Set Blower motor ON HIGH

-

Open all A/C outlets

-

Depress A/C and WASH buttons simultaneously for 5 Seconds (Until all LED's light)

Results:
-

All LED's will turn on for 5 Seconds.

-

Cooldown test is running if A/C and RECIRC are alternately flashing.

-

Acceptable result is when LED flashing stops.

-

Calibration Diagnostics and Cooldown must be run separately.

CALIBRATION DIAGNOSTICS AND COOLDOWN ABORT

Test can be aborted by doing one of the following:

Control Assembly, HVAC|Diagrams|Page 4883 > < Control Assembly, HVAC|Diagrams|Page 4881