chrysler Workshop Repair Guides

Chrysler Workshop Service and Repair Manuals

Downstream Oxygen 1/2 Sensor Replacement|Page 696 > < Downstream Oxygen 1/2 Sensor Replacement
Page 2
background image

Fig. 47 Oxygen Sensor Removal/Installation

4. Use a socket such as Snap-On YA8875 or equivalent to remove sensor.
5. When the sensor is removed, the exhaust manifold threads must be cleaned with an 18 mm X 1.5 + 6E tap. If using original sensor, coat the

threads with Loctite 771-64 anti-seize compound or equivalent.

INSTALLATION

New sensors are packaged with compound on the threads and no additional compound is required.
1. Install sensor and tighten to 27 Nm (20 ft lbs.) torque.
2. Connect the electrical connector.
3. Install gromment.
4. Lower vehicle.

Downstream Oxygen 1/2 Sensor Replacement|Page 696 > < Downstream Oxygen 1/2 Sensor Replacement