Town & Country Van V6-229 3.8L VIN L MFI (1995)
Vapor Canister Hose Connections
EVAP CANISTER CONTROL VALVE TEST
1. Disconnect 3/16" vacuum hose from canister and connect a vacuum pump to nipple.
2. Apply 10 inches of vacuum.
3. If valve does not hold vacuum, replace canister.