chrysler Workshop Repair Guides

Chrysler Workshop Service and Repair Manuals

HCU (Hydraulic Control Unit)|Page 5177 > < Electronic Brake Control Module|Locations|Page 5172
Page 1
background image

Hydraulic Control Assembly - Antilock Brakes: Description and Operation
HCU (Hydraulic Control Unit)

HYDRAULIC CONTROL UNIT

The hydraulic control unit (HCU) contains the valve block assembly, and pump/motor assembly. The HCU is attached to the CAB.

Valve Block Assembly: The valve block assembly contains valves with four inlet valves and four outlet valves. The inlet valves are spring-loaded in
the open position and the outlet valves are spring loaded in the closed position. During an antilock stop, these valves are cycled to maintain the proper
slip ratio for each wheel. If a wheel detects slip, the inlet valve is closed to prevent and further pressure increase. Then the outlet valve is opened to
release the pressure to the accumulators until the wheel is no longer slipping. Once the wheel is no longer slipping, the outlet valve is closed and the
inlet valve is opened to reapply pressure. If the wheel is decelerating within its predetermined limits (proper slip ratio), the inlet valve will close to
hold the pressure constant. On vehicles, which are equipped with a traction control system, there are two additional valves that isolate the master
cylinder and rear wheels. During a traction control event the brakes are applied to reduce wheel slippage.

Pump Motor Assembly: The pump motor assembly provides the extra amount of fluid needed during antilock braking. The pump is supplied fluid
that is released to the accumulators when the outlet valve is opened during an antilock stop. The pump is also used to drain the accumulator circuits
after the antilock stop is complete. The pump is operated by an integral electric motor. This motor is controlled by the CAB. The CAB may turn on the
pump motor when an antilock stop is detected. The pump continues to run during the antilock stop and is turned off after the stop is complete. Under
some conditions, the pump motor will run to drain the accumulators during the next drive off. The CAB monitors the pump motor operation internally.

HCU (Hydraulic Control Unit)|Page 5177 > < Electronic Brake Control Module|Locations|Page 5172