Blower Motor Grommet - Typical

8. Push the rubber grommet through the hole in the lower air inlet housing.

9.

Route the blower motor wire lead through the opening in the lower air inlet housing and remove the lower air inlet housing from vehicle.

10. Position the recirculation-air door as necessary to access and remove the three screws that secure the blower motor to the lower half of the HVAC

housing.

11. Gently flex the recirculation air door downward to gain access to remove the blower motor from the housing.

NOTE: To aid in installation, note the position of the blower motor mounting tabs prior to removal.

Blower Motor Mounting Tabs

12. Remove the blower motor from the HVAC housing by rotating and tilting the blower motor as necessary.

INSTALLATION

1. Gently flex the recirculation air door far enough to position the blower motor and wheel into the lower half of the HVAC housing.
2. Position the recirculation-air door as necessary to install the three screws that secure the blower motor to the blower housing in the lower half of

the HVAC housing. Tighten the screws to 2 N-m (17 in. lbs.). 

3. Reach through the fresh air intake opening to access and engage the upper pivot receptacle of the recirculation-air door with the pivot post of the

upper intake air housing. 

4. Feed the blower motor wire harness connector through the grommet hole in the lower intake air housing and seat the rubber grommet
5. Position the lower intake air housing onto the HVAC housing and upper intake air housing. Be certain that the splined output shaft of the 

recirculation door actuator is properly engaged with the splined receptacle on the bottom of the recirculation-air door. 

6. Install the three screws that secure the lower air intake housing to the lower half of the HVAC housing. Tighten the screws to 2 N-m (17 in. lbs.).
7. Install the two screws that secure the upper intake air housing to the lower intake air housing. Tighten the screws to 2 N-m (17 in. lbs.). 