Blower Motor: Service and Repair
Heating and Ventilation System

REMOVAL PROCEDURE

1. Disconnect the negative battery cable.

2. Disconnect the blower motor electrical connector.
3. Remove the blower cooling hose.
4. Remove the screws that secure the motor to the heater/air distribution case.

5. Remove the motor and the seal from the heater/air distribution case by gently pulling the motor straight down and out.

INSTALLATION PROCEDURE

1. Install the blower motor and the seal, with the shock mount pads, in the heater/air distribution case. Hold the blower motor in position.

2. Install the screws to secure the blower motor to the heater/air distribution case.

Tighten
Tighten the blower motor retaining screws to 6 N.m (53 lb-in).

3. Install the blower motor cooling hose.
4. Connect the electrical connector.
5. Connect the negative battery cable.
6. Confirm that the blower motor operates properly.

Heating and Ventilation System|Page 2779 > < Tightening Specifications|Page 2773