8. Install a new O-ring and mate the discharge hose to the condenser pipe connector block.

9. Install the discharge hose condenser pipe connector block retaining nut.

Tighten
Tighten the discharge hose-to-condenser pipe connector block retaining nut to 16 N.m (12 lb-ft).

10. Mate the A/C system hose connector block to the compressor. Hold it in place while tightening the retaining nut.

Tighten
Tighten the A/C system hose connector retaining nut to 33 N.m (24 lb-ft).

11. Connect the negative battery cable.

12. Evacuate and recharge the A/C system. Refer to "Discharging, Adding Oil, Evacuating, and Charging Procedures for A/C System".

Housing Assembly HVAC > < Handling of Refrigerant Lines and Fittings|Page 2859