Leganza CDX L4-2.2L DOHC D-TEC MFI (1999)
Intake Manifold: Service and Repair
REMOVAL PROCEDURE
1. Remove the fuel pump fuse.
2. Start the engine. After it stalls, crank the engine for 10 seconds to rid the fuel system of fuel pressure.
3. Disconnect the negative battery cable.
4. Disconnect the Evaporative (EVAP) emission canister purge solenoid from the intake manifold and loosen the bracket bolt.
5. Drain the engine coolant. Refer to Cooling System.
6. Disconnect the Intake Air Temperature (IAT) sensor connector.
7. Disconnect the air intake tube from the throttle body.
8. Disconnect the Idle Air Control (IAC) valve connector.
9. Disconnect the Throttle Position Sensor (TPS) connector.