Leganza CDX L4-2.2L DOHC D-TEC MFI (1999)
7. Remove the eight bolts from the valve body cover, then remove the cover.
8. Disconnect the four electrical connectors from valve body solenoids.
9. Remove the two suction cover retaining bolts and the suction cover.
Caution: Use care not to damage the manual valve connecting rod or the lever.