Leganza SE L4-2.2L DOHC D-TEC MFI (2001)
EGR Valve: Service and Repair
Removal Procedure
1. Disconnect the negative battery cable.
2. Disconnect the vacuum hose from the exhaust gas recirculation (EGR) valve.
3. Remove the EGR valve retaining bolts.
4. Remove the EGR valve from the electronic ignition (EI) system ignition coil adapter.
Installation Procedure
1. Clean the EI system ignition coil adapter mating surface.
2. Install a new EGR valve gasket.
3. Install the EGR valve with the bolts.
Tighten
Tighten the exhaust gas recirculation valve retaining bolts to 22 lb-ft (30 N.m).
4. Connect the vacuum hose to the EGR valve.
5. Connect the negative battery cable.