daewoo Workshop Repair Guides

Daewoo Workshop Service and Repair Manuals

Maintenance and Repair|Page 2689 > < Maintenance and Repair|Page 2687
Page 12
background image

Tighten the starter solenoid assembly screws to 8 N.m (71 lb-in).

13. Install the field coil connection to the starter terminal. Install the nut.

Tighten
Tighten the starter field connector nut to 8 N.m (71 lb-in).

14. Position the armature assembly into the field frame.
15. Place the shield on the armature and field frame assembly.
16. Install the armature and field frame assembly with the shield into the starter housing.

17. Position the commutator end frame and brush holder assembly, lining up the end frame holes with the through-bolt holes in the housing.

Maintenance and Repair|Page 2689 > < Maintenance and Repair|Page 2687