Leganza SE L4-2.2L DOHC D-TEC MFI (2001)
7. Position the transmission fluid temperature (TFT) sensor protector bracket, then install the nut and bolt.
-
Tighten the TFT sensor protector bracket nut and bolt to 15 - 22 ft. lbs. (20 - 29 Nm).
8. Install the engine under cover.
9. Lower the vehicle.
10. Connect the negative battery cable.
11. Fill the transaxle with fluid.