Leganza SX L4-2.2L DOHC D-TEC MFI (1999)
Valve Cover: Service and Repair
REMOVAL PROCEDURE
1. Disconnect the negative battery cable.
2. Disconnect the breather tube from the valve cover.
3. Disconnect all of the necessary vacuum lines.
4. Remove the spark plug cover bolts.
5. Remove the spark plug cover.
6. Disconnect the ignition wires from the spark plugs.
7. Remove the power steering hose clamp bolt and the position power steering hose clamp clear of the repair area.
8. Disconnect the Camshaft Position (CMP) sensor connector.
9. Remove the valve cover bolts.
10. Remove the valve cover washers.
11. Remove the valve cover.
12. Remove the valve cover gasket from the valve cover.