2. Install the auxiliary catalytic converter lower flange bolts.

Tighten
Tighten the auxiliary catalytic converter-to-connecting pipe nuts to 40 Nm (30 ft. lbs.).

3. Install the splash guard.
4. Lower the vehicle.

5. Install the auxiliary catalytic converter upper flange bolts.

Tighten
Tighten the auxiliary catalytic converter-to-exhaust manifold nuts to 40 Nm (30 ft. lbs.).

6. Connect the post-converter heated oxygen sensor electrical connector.