Nubira CDX Wagon L4-2.0L DOHC D-TEC MFI (2000)
A/C Pressure Transducer: Service and Repair
Removal
1. Disconnect the negative battery cable.
2. Remove the air cleaner housing.
1. Disconnect the hose to the intake manifold.
2. Remove the air cleaner housing retaining bolts.
3. Lift out the housing.
3. Discharge and recover the refrigerant.
4. Release the connector lock and pull the transducer wire connector out.
5. Remove the transducer with a wrench.
6. Discard the O-ring seal.
Installation