A/C Pressure Transducer: Service and Repair

Removal

1. Disconnect the negative battery cable.

2. Remove the air cleaner housing.

1. Disconnect the hose to the intake manifold.
2. Remove the air cleaner housing retaining bolts.
3. Lift out the housing.

3. Discharge and recover the refrigerant. 
4. Release the connector lock and pull the transducer wire connector out.

5. Remove the transducer with a wrench.
6. Discard the O-ring seal.

Installation

A/C Pressure Transducer <--> [Refrigerant Pressure Sensor / Switch, HVAC]|Service and Repair|Page 3118 > < Refrigerant Oil|Capacity Specifications|Page 3114